About 76,300 results
Open links in new tab
  1. Introduction to Modbus and Modbus Function Codes

    Jan 30, 2023 · Introduction to Modbus and Modbus Function Codes Modbus is one of the oldest industrial communication protocols still in use today. Continue reading to find out how the protocol …

  2. Modbus: The Original Industrial Fieldbus Protocol

    Sep 2, 2025 · This article introduces Modbus, an industrial protocol that laid the foundation for fieldbus communication in industrial systems.

  3. Choosing an Interface: Why Modbus is Still Around After 40 Years

    Mar 19, 2021 · Learn about the advantages of Modbus over newer protocols when choosing an interface with third-party devices.

  4. Introduction to Modbus | Digital Data Acquisition and Networks in ...

    Modbus data frames The Modbus communication standard defines a set of commands for reading (receiving) and writing (transmitting) data between a master device and one or more slave devices …

  5. How-To: Building a PLC Project with Modbus Communication

    Apr 5, 2022 · Modbus is a communication protocol stemming from the early days of Modicon PLCs, but is still common today. These two example implementations of Modbus transactions will get you started.

  6. Modbus client application | Automation & Control Engineering Forum

    Jan 9, 2024 · Open Modbus adds two other IEEE754 32 bit floating formats with its LE button which selects between Big Endian and Little Endian. Win-tech two standard FP formats correspond to the …

  7. Modbus over Ethernet | Automation & Control Engineering Forum

    Jun 25, 2008 · Modbus is a protocol. You can use Modbus protocol over Ethernet, it is then called Modbus TCP/IP. Commonly used by Schneider Electric, as Schneider bought the company Modicon, …

  8. Communication problems , modbus timeout error

    Aug 14, 2020 · Modbus slave never have a slave node address zero, by definition. If you have more one slave, wire and connect to only one slave initially to get comm up and running.

  9. Confused: Modbus TCP vs. Modbus RTU Over TCP - Control.com

    May 19, 2011 · Modbus RTU over TCP/IP is typically used by serial servers where you can have an Modbus Ethernet client communicating with multiple Modbus RTU- RS485 slaves, by way of a serial …

  10. Timeout error | Automation & Control Engineering Forum

    Feb 10, 2025 · Modbus Poll is a Modbus master simulator. If your ESP32 is indeed a master, then this won't work, as a Modbus master cannot communicate to another Modbus master.